A press fit is a joint with no fastener, no thread, and no adhesive. Two parts are held together by interference alone: the shaft is slightly larger than the bore, and pressing them together creates a friction grip that holds the assembly. It is a clean, compact joint, and it is also a joint that is entirely decided by two numbers — the bore size and the shaft size — and by the difference between them. A press fit specified as “tight fit” is not a specification. A press fit specified as a fit designation, with the assembly method and the inspection agreed, is a joint that will hold.
How a press fit holds
A press fit works because the shaft is larger than the bore by a small amount, called the interference. When the shaft is pressed into the bore, both parts deform elastically: the bore stretches slightly, the shaft compresses slightly, and the contact pressure between them creates friction. That friction resists pull-out and rotation. The larger the interference, the greater the contact pressure and the stronger the hold — and the greater the force needed to assemble the parts, and the greater the stress in the material.
That stress is the limit. Too little interference and the joint slips under load. Too much and the bore cracks, the shaft yields, or the parts cannot be assembled at all. Brass is forgiving here: it is ductile and machines cleanly, and a brass bushing pressed into a steel housing or onto a steel shaft is a common, reliable joint. But the interference must be chosen for the materials and the load, not copied from another joint. A press fit that works in brass into steel will not necessarily work in brass into brass, or in stainless steel into aluminum, because the stiffness and the strength of the materials are different.

The ISO 286 fit system: a common language for fits
The ISO 286 fit system gives buyers and suppliers a common language for fits, and it is the language Precimora already uses for sliding fits — H7/g6 or H7/h6, as stated on the bushings page. The system works the same way for press fits: a letter and a number for the hole, and a letter and a number for the shaft, and the combination defines the clearance or interference. H7/p6 is a standard interference-fit designation in the same system: the H7 hole and the p6 shaft overlap by a small, defined amount, producing a light press fit that can be assembled with a press and holds against moderate loads.
The point of using the standard designations is that they are unambiguous. “H7/p6” means the same thing to every machinist, and the tolerance values for each designation are published in the standard. A buyer who states the fit designation does not need to state the individual tolerances — the designation carries them. But the designation must be confirmed with the supplier, because the right fit depends on the materials, the lengths, and the loads, and a designation that is right for one joint may be wrong for another. State the designation, state the materials, and ask the supplier to confirm the fit in the engineering review.
Interference: how much is enough, and how much is too much
The interference — the amount by which the shaft exceeds the bore — is the single most important number in a press fit, and it is also the number most often left unstated. A light press fit, where the interference is small, assembles with moderate force and holds against light loads. A heavy press fit, where the interference is larger, holds against heavy loads but needs a large press force and risks cracking a thin-walled bore or yielding a slender shaft.
Three things decide the right interference: the materials, the length of engagement, and the load. A longer engagement spreads the contact over more area and holds more, so a short bushing needs more interference than a long one for the same hold. A harder material tolerates more interference without yielding. A joint that must resist torque needs more interference than one that must resist only pull-out. State all three in the RFQ — the materials of both parts, the length of the engagement, and the load the joint must carry — and the supplier can confirm the fit designation that matches. A press fit specified by interference alone, without the materials and the load, is a number without a context.
Assembly: pressing, heating, and cooling
How a press fit is assembled matters as much as the fit itself. The common methods are pressing at room temperature, heating the bore so it expands, or cooling the shaft so it shrinks. Pressing at room temperature is the simplest, but it needs the parts to be aligned before the press starts — a shaft that enters the bore at an angle will gall, scoring both surfaces and ruining the fit. A lead-in chamfer on the shaft and a chamfer on the bore mouth help the parts align, and they should be on the drawing.
Heating the housing or cooling the shaft is used where the interference is large or the parts are delicate. A heated bore expands and the shaft slides in freely; as the bore cools, it grips the shaft. A cooled shaft shrinks and drops into the bore; as it warms, it expands into the grip. Both methods avoid the galling risk of pressing, but they need the temperature change stated and controlled, and they need the parts to be assembled quickly before the temperatures equalise. State the assembly method in the RFQ if it matters — for example, where the parts cannot be pressed because the assembly is fragile — and agree it with the supplier before production.

Inspection: what to measure, and when
A press fit cannot be inspected after assembly by measuring the bore and the shaft separately, because they are already together. The inspection must happen before assembly: measure the bore, measure the shaft, and confirm the interference is within the intended range. That is the check that matters, and it should be in the inspection plan.
After assembly, the checks are functional: does the joint hold the specified pull-out load, does it resist the specified torque, and is the assembly aligned? A press fit that was assembled with the shaft at an angle may hold but run out of true, so a runout check after assembly is worth agreeing where the part must run true. The companion post on concentricity, runout, and datums covers the geometric check; for a press fit, the point is that the check happens after assembly, on the assembled part, not on the individual pieces.
Common pitfalls and how to avoid them
The most common pitfall is specifying “tight fit” or “press fit” with no fit designation, so the interference is a guess. State the fit designation, such as H7/p6, and confirm it in the review.
The second is copying an interference value from a different joint, with different materials or a different engagement length. State the materials, the engagement length, and the load, and let the fit follow from them.
The third is a press fit into a thin-walled bore, where the interference cracks the wall. State the wall thickness and ask the supplier to confirm the bore can take the interference.
The fourth is pressing a shaft into a bore without a lead-in chamfer, so the shaft enters at an angle and galls. Put a chamfer on the shaft end and on the bore mouth.
The fifth is inspecting the fit after assembly, when the parts can no longer be measured separately. Measure the bore and the shaft before assembly, and check the assembled joint functionally.
The sixth is forgetting that a press fit is permanent. A pressed joint cannot be disassembled without damage, so if the assembly must come apart for service, a press fit is the wrong joint. State whether the joint must be serviceable, and choose a different joint if it must.

Buyer checklist
- The fit is stated as a standard ISO 286 designation (for example H7/p6), not as “tight fit”.
- The materials of both parts are stated, so the interference suits the pair.
- The length of engagement is stated, because a longer engagement holds more.
- The load the joint must carry — pull-out, torque, or both — is stated.
- The wall thickness of the bore is stated, so the interference cannot crack it.
- A lead-in chamfer is on the shaft end and on the bore mouth.
- The bore and the shaft are measured before assembly, and the interference is confirmed.
- Whether the joint must be serviceable is stated — a press fit is permanent, so a serviceable joint needs a different design.